Why this matters

Give every surveyed door a unique identifier and use it consistently in photographs, measurements and drawings. Without this, information from similar doors is easily mixed.

What to confirm

Photograph the full door from both sides, the edge, frame, lock area, strike, hinges, closer, surrounding hardware and cable route. Write down dimensions; a tape measure appearing in a photograph is not enough.

A practical working method

Check whether the door is healthy before designing the retrofit. Sagging, distortion, damaged frames or excessive closing force may need correction independently of the new lock.

Records, acceptance and handover

For electromechanical work, record power, cable, controller and commissioning conditions. Have both hardware and control-system personnel review the survey, then test the most uncertain door first.

Evidence and scope

This article is intended for preliminary product and project discussions. Product functions, performance, certification, compatibility and availability must be checked against current documentation for the selected model and the actual project requirements. Application examples are not claims of completed customer projects.